1 used symbols, 2 important recommendations, 1 aeration – DE DIETRICH ELITEC DTG 130 User Manual
Page 3: 1 chimney versions, 2 forced flue versions, Used symbols, Important recommendations
3
20/02/09 - 300004565-001-C
DTG 130
2. Important recommendations
Congratulations on your choice of a high quality product. We strongly advise you to read the following instructions in order to
guarantee the optimal operation of your appliance. We are sure that it will be entirely to your satisfaction and will meet with all of
your expectations.
1 Used symbols
Caution danger
Risk of injury and damage to equipment. Attention must be
paid to the warnings on safety of persons and equipment.
Specific information
Information must be kept in mind to maintain comfort.
Z
Reference
Refer to another manual or other pages in this instruction
manual.
2 Important recommendations
For a proper operating of the boiler, follow carefully the
instructions.
Any intervention on the appliance and heating equipment
must be carried out by a qualified technician.
The manufacturer is not liable for any improper use of the
appliance or failure to maintain or install the unit correctly
(the user shall take care to ensure that the system is
installed by a qualified fitter).
Check the seal on the gas and water pipe connections.
Check that the appliance is properly set for the type of gas
used.
Keep to the polarity shown on the terminals: phase (L),
neutral (N) and earth
4
.
Check regularly that the installation contains water and is
pressurised.
Burn hazard in direct contact with the flame inspection
window.
To guarantee protection against the corrosion of domestic
hot water calorifiers fitted with a titanium anode (Titan
Active System ® protection system), always leave the
control panel switched on.To switch off the heating or the
domestic hot water, use the Summer or Antifreeze mode.
Forced flue versions: Check the air flap setting.
2.1 Aeration
2.1.1
Chimney versions
Do not obstruct the air inlets in the room (even partially).
France: the cross section of the aeration vent, which is compulsory
in the boiler room in which the boiler is installed, must comply with the
DTU 61.1 (P 45 204) standard and, in particular, with the instruction
on boiler room layout (Book 1764 April 1982).
Belgium:the cross-section of the aeration vents, which are
compulsory in the room in which the boiler is installed, must comply
with the NBN D51-003 standard.
Germany: the cross section of the ventiliation vents, which are
compulsory in the room in which the boiler is installed, must comply
with the VDI 2050 form 1 standard and with other prevailing
regulations
Other countries: the cross section of the aeration inlet, which is
compulsory in the premises in which the boiler is installed, must
comply with the standards in force in the country.
2.1.2
Forced flue versions
It is not necessary to provide ventilation of the premises in which the
boiler is installed. Ventilation is required if a mechanical connection
to the gas exists.