Danger – EBARA EFQT3 User Manual
Page 14

EBARA Fluid Handling
14
Figure 6C. – Alignment of V-Belt Driven Pumps
MISALIGNED:
SHAFTS NOT PARALLEL
MISALIGNED:
SHAFTS NOT IN LINE
ALIGNED:
SHAFTS PARALLEL AND
SHEAVES IN LINE
Tighten the belts in accordance with the belt
manufacturer’s instructions. If the belts are
too loose, they will slip; if the belts are too
tight, there will be excessive power loss and
possible bearing failure. Select pulleys that
will match the proper speed ratio; over
speeding the pump may damage both pump
and power source.
Do not operate the pump without the guard
in place over the rotating parts. Exposed
rotating parts can catch clothing, fingers, or
tools, causing severe injury to personnel.
DANGER!