beautypg.com

Ddlfu/ddlfmu – EBARA DDLFMU User Manual

Page 15

background image

Ebara Submersible Sewage Pumps

DDLFU/DDLFMU

Instruction Manual

Ebara

Fluid Handling

www.pumpsebara.com

15

(803) 327-5005 • (803) 327-5097

(fax)

rev. 10/11

Leakage Detector

1. Construction:

Each switch has a magnet-containing float which senses the liquid level and magnetically actuates a dry reed switch
encapsulated within a stem. The switch opens on rise of liquid.

2. Specifications

• apply to 2 to 10HP

breaking Capacity

: aC50Va, DC50W

Max. breaking Current

: aC0.5a, DC0.5a

Max. Operating Voltage

: aC300V, DC300V

2.

• apply to 15 to 60HP

breaking Capacity

: aC12Va, DC10W

Max. breaking Current

: aC0.6a, DC0.5a

Max. Operating Voltage

: aC200V, DC200V

Lead Wire

Float Body

(304 S.S.)

Float

(304 S.S.)

Stopper

(304 S.S.)

Lead Wire

Float Body

(Polypropylene)

Float

(Polypropylene)

Stopper

(316 S.S.)

Open

Close

Close

Open

This manual is related to the following products: