Maintenance and Service

6. Disassembly and assembly:

Please contact the following for assistance:

Ebara International Corporation
Customer Service Manager
1651 Cedar Line Drive
rock Hill, South Carolina 29730

Thermal Protection

The motor shall be equipped with a protector such as automatic cut-off device and thermal protector. The motors described
below shall incorporate Miniature Thermal Protectors (MTP) which are embedded in the windings.

When temperature of the winding raises and reaches the MTP acting point, the motor protection circuit is activated to protect
motor from over heat.

1. applicable model

Model: DGFU, DLFU, DVFU, DDLFU

2. MtP Specifications:

Model

KLIXON 9700K-66-215

Type of Contact

b (Normal-contact acting-open)

acting Temperature

140±5° C (284±9° F)

re-setting Temperature

85±10° C (185±18° F)

Capacity of Contact

3. installation:

MTP shall be embedded in the stator windings as
shown at right –

4. Construction:

Construction of the MTP is as shown below:

Caution

all service should be done by factory trained or qualified personnel only.
be sure to cut off power source before beginning disassembly.

Voltage (V)

Amperage (A)

DC 24

18

AC 115

18

AC 230

13

AC 460

5.5