Installation Instructions
4
INSTALLATION
WARNING:
FAILURE TO PROVIDE ADEQUATE
STRUCTURAL STRENGTH FOR THIS COMPONENT CAN
RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE
TO EQUIPMENT! It is the installer’s responsibility to make
sure the structure to which this component is attached can
support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
NOTE:
The PAC391 is compatible with the following wall
brackets: RMF1, RMT1, RLF1, RLT1 and Standard
Slat Walls.
1.
Verify mounting brackets on wall bracket (A) can move
freely. (See Figure 1)
Figure 1
2.
Locate desired installation location and slide upper
mounting plate into wall making sure bracket is seated in
channel bottom. (See Figure 2)
3.
Let lower mounting plate rest against wall.
4.
Using 1/2" socket, tighten tension screw until lower
mounting plate slides into channel in wall and continue
tightening until resistance is felt. (See Figure 2)
Figure 2
5.
Tighten two upper and lower button head cap screws to
secure wall bracket (A) to wall. (See Figure 3)
6.
Repeat for second wall bracket (A).
Figure 3
x 4
(A)
1
(A)
2
3
4
(A)
4
x4
A
5
5