Faults, Technical data – KOSPEL EPJ.P-PRIMUS User Manual
Page 18
18
Faults
In case the heater does not heat the water, check for possible reasons:
-
a failure of the mains supplies (e.g. fuses),
-
insufficient flow rate through the heater (e.g. dirty filter, incorrect setting of the
flow regulating valve) - see „Flow regulation”.
The warranty does not cover the above repairs.
If there is a fault in the appliance (the heater does not work and all the above reasons
do not occur), contact the seller.
Technical data
EPJ.P - ...... - shower
EPJ.P-....u - shower + washbasin
Water heater EPJ.P Primus
4,4
5,5
Rated power
kW
4,4
5,5
Rated voltage
230V~
Rated current
A
19,1
23,9
Min. supply water pressure
MPa
0,12
Safety class
IP25
Operating point
l/min
1,8
2,2
Efficiency (at Δt = 30°C)
l/min
2,1
2,7
Overall dimension (height without tap set x width x depth) mm
218 x 214 x 95
Weight (heater + fittings)
kg
2,2 ÷ 0,6
Connection to the mains by supply cord (1,2m)
mm
2
3 x 2,5
The maximum allowed network impedance
Ω
0,34
0,31
Water supply pipe section
G1/2"