9
○
1 AC Outlet: Connects to AC 115V or AC230V power source. The supply transformer has
been designed for use on either 115Vac or 230Vac, selected by slide switch on rear panel. The
amplifier is factory set at 230Vac mains voltage.
The connection cable must be fitted with an in-line fuse. Quick blow type F10A when
Connecting batteries please ensure correct polarity.
○
2 Grounding Screw: Connects to earth-ground by shorter than 10 feet 16AWG or thicker cable.
○
3
DC24V Input: Connect DC24V backup battery to keep on the system operation when power
failed.
When using the external backup batteries please earth the amplifier via the screw terminal,
because of the high voltages present. Electrical stability of the system is increased by earthing
the case.
○
4
Speaker Output Terminal: Select and turn on the Zone #1 - Zone#8 speakers output from P.A.
DVR software; the total audio level is 120W and the input voltage is AC100V (Default) / 70V.
○
8
○
1
○
2
○
3
○
4
○
5
○
7
○
6
○
9
○
10
○
11
○
12
○
13
○
14