beautypg.com

BatteryMINDer 48021 User Manual

Page 7

background image

BatteryMINDer

®

Models 36271 & 48021

Rev. C-070313

Page 7

P/N VDC36271/48021-MNL

QUALIFYING YOUR BATTERY:

Preliminary Requirements

NOTE: The BatteryMINDer has no electrical output unless it is connected to
a healthy battery. Testing the BatteryMINDer with a volt or an Amp meter
without the unit being connected across a good battery will result in a false
reading. If you experience any problems, or are not sure of how to properly
use or connect your BatteryMINDer, please e-mail our technical support at:
[email protected] or call our toll-free technical support line
800-379-5579 x6 (Eastern Time).

Be certain to leave your phone number

with the area code, time zone and the best time to call.

To gain the best result from your new charger and to maximize the life and
performance of your batteries we strongly recommend you qualify (test)
your batteries before attempting to either charge-maintain or desulfate them.
Remember, even if you just purchased a “new” battery it may have been
subjected to conditions that have caused “sulfation” such as high temperature
(>=80°).

NOTE: If your battery is new and you are certain it was not subject to

conditions that could have caused sulfation*, even before you purchased

it, then you can disregard our recommendations for qualifying / testing

your battery, before using the BatteryMINDer.

* Such as high temperature storage (=/> 80°F) and/or allowed to self-
discharge to

37.2 Volts

/

49.6 Volts

or lower.

Testing a Filler Cap or Manifold-type Lead Acid Battery

1. Carefully remove all caps from your battery.
2. Check the water-liquid electrolyte level. If the level is low or has ever

been below top of plates, severe lead plate sulfation has taken place.
Significant recharge/reconditioning time is needed to restore these plates
to a condition where the battery can be expected to function normally.

3. Refill each cell with distilled water only to the liquid level indicator found in

each cell.

Before proceeding further you must be thoroughly familiar

with the safety and operating instructions.

4. Recharge the battery with the BatteryMINDer to ensure that it is slowly

and completely charged before you determine its condition. Allow battery
to “rest” (see

Glossary of Terms) overnight for a minimum of 12 hours

before testing with a temperature compensated hydrometer and/or digital
type voltmeter only.