beautypg.com

BatteryMINDer OBD-12, -24, -36 & -48 User Manual

Page 5

background image

Rev. H-041409

Page

`

P/N VDC OBD12-24-36-48-MNL

BatteryMINDer

Models OBD12-24-36-48

4. Recharge the battery to ensure that it is
completely charged as possible before you determine
its condition. Allow battery to “rest”* overnight
for a minimum of 12 hours before testing with a
temperature compensated hydrometer and/or digital
type voltmeter only.

* “RESTED” = a battery that has been as fully
charged as possible, using a 3 stage charger or your
alternator and left disconnected from charger or any
type load for a minimum of 12 hours before testing.

. If the BatteryMINDer battery condition LED lights

YELLOW

(single battery) or no balls float in one or

more cells, your battery may be too far gone to be
fully desulfated. Use a hot/cold calibrated hydrometer
tester for the most accurate results** (see next page)
if you see an increase in the Specific Gravity (SG) or
voltage indicating that there is an improvement in
the battery’s condition, continue desulfating for an
additional 72 hours and retest the battery. Continue
this process until the SG or voltage readings no
longer increase.

Temp. Compensated

Hydrometer - meter

or 4 ball type

6-V

3

cells

8-V

4

cells

12-V

6

cells

Full Capacity

Percentage

1.270 (4 Balls

floating)

6.3V

8.4V

12.6V

100%

1.250 (3 Balls

floating)

6.18

8.26

12.4

75%

1.190 (2 Balls

floating)

6.09

8.13

12.2

50%

1.150 (1 Balls

floating)

6.0

8.0

12.0

25%

1.120 (0 Balls

floating)

5.88

1

7.84

1

11.8

1

0%

1

May denote shorted cell or battery that has been severely

discharged and may not be recoverable

OCV = Open Circuit No Load Voltage

OCV = Open Circuit No Load Voltage