beautypg.com

Troubleshooting – BVA Hydraulics IMP2514, IAP2514, IEP2514, IEPS2514 User Manual

Page 6

background image

6

TrOUBLESHOOTInG

A system failure may or may not be the result of a pump malfunction. The following information is intended

to be used as an aid in determining if a problem exists. For repair service, contact a BVA authorized service

center.

Symptom

Possible Causes

Corrective Action

Erratic cylinder action

• External leak
• Internal hydraulic leak

• Follow pump instructions for
bleeding air
• Tighten all connections
• Contact Service Center

Pump or cylinder fails to
maintain pressure

• Overload condition
• External leak
• Internal hydraulic leak
• Cylinder seals leaking
• Pump or valve malfunctioning

• Remedy overload condition
• Tighten all connections
• Contact Service Center
• Contact Service Center
• Check pump operating instructions

Cylinder extends partially

• Hydraulic oil level too low in pump
• Load is above the capacity of system
• Cylinder is sticking or binding

• Fill and bleed the system
• Match the capacity to application
• Contact Service Center

Cylinder moves slower than
normal

• Loose connection or coupler
• Restricted hydraulic line or fitting
• Pump not working correctly
• Cylinder seals leaking

• Tighten connection or coupler
• Clean and replace if damaged
• Check pump operating instructions
• Replace cylinder

Cylinder leaks hydraulic fluid

• Worn or damaged seals
• Linkage binding
• Loose couplers
• Malfunctioning coupler

• Contact Service Center
• Lubricate all moving parts
• Tighten couplers
• Depressurize pump and hose, remove
application, install new coupler

Cylinder will not retract or
retracts slower than normal

• Weak or broken retraction spring,
Cylinder damaged internally
• Pump reservoir too full

• Contact Service Center
• Contact Service Center
• Drain hydraulic fluid to correct level

Motor will not start (Model

IEPD2506, IEP2514 &

IEPS2514)

• No power/incorrect voltage

• Damaged power cord

• Tripped circuit breaker

• Loose or faulty wiring

• Check power supply and voltage

• Contact Customer Service

• Ensure breaker is adequate size

• Contact Customer Service

Motor cuts out (Model

IEPD2506, IEP2514 &

IEPS2514)

• Extension cord too long

• Faulty motor

• Overheated motor trips breaker

• Replace with shorter cord

• Replace or repair motor

• Allow motor to cool, reset circuit breaker

This manual is related to the following products: