Manual Pumps

Hand

Pump

Model

Usable

Oil

volume

(in

3

)

Pressure rating

(psi)

Oil Displacement

(in

3

)

Oil Outlet Port

Thread

Weight

(lbs)

1st Stage 2nd Stage 1st Stage 2nd Stage

P1000

61.0

200

10,000

0.81

0.14

3/8”-18 NPTF

13.2

P2001

122.0

24.2

P2301M

128.0

32.3

Air Pumps

Air Pump Model

Usable Oil

volume

(in

3

)

Pressure rating

(psi)

Oil Output Flow

rate (in

3

/min)

Input Air Pressure

range

(psi)

Weight

(lbs)

no Load

Load

PA1500

91.5

10,000

66

11

110 - 175

18.1

Electric Pumps

Electric

Pump

Model

Capacity

(gal)

Pressure rating

(psi)

Oil Output Flow

rate (in

3

/min)

valve

Type

Motor

Size

(hp)

Current

Draw

(A)

Motor

voltage

(v)

Weight

(lbs)

1st Stage 2nd Stage 1st Stage 2nd Stage

PEM0501T

1

350

10,000

293

18

4-way,

3-pos

0.5

9

115/125

60

PEW0501T

3-way

3-pos

PESL0501T

nOTICE:

The power retract feature of the IMPD2506 and IEPD2506 Shop Presses is not intended to be used

under load. Never pull or raise a workpiece with the power retract feature.

ASSEMBLY

1. Adjust bed frame to lowest position and slacken winch cable.

2. Install the winch assembly to the press using 3 bolts, washers and nuts.

3. Secure cylinder to the cylinder adapter plate, and mount the adapter plate to upper cross member using 4 bolts

and washers.

nOTICE: The cylinder comes with carrying handles, loosen Allen head socket screw to remove the handles.

4. Attach base sections to upright channels with 4 bolts and nuts.

5. Attach lower cross member to upright channels with 4 bolts and nuts.

6. Attach and secure the pump bracket with bolts, nuts & washers provided. (Model IMP2506 & IMPD2506 only)

7. Connect pressure gauge and hydraulic hose to gauge adapter, then connect gauge adapter to pump.
nOTICE: Use thread tape or compound on all connections.
8. For Model IMP2506, IMP2514 & IMPD2506: Place pump on pump bracket and connect hydraulic hose end to

cylinder.

CAUTIOn: Before disassembly, slide bed frame section down to lowest position.

OPErATIOn

Before Use

1. Inspect before each use. Do not use if bent, broken or cracked components are noted. Check for and tighten any

loose assemblies. Replace worn or damaged parts and assemblies with BVA authorized replacement parts only.

2. Verify that the product and the application are compatible, if in doubt contact BVA Technical Service (816) 891-6390.

3. Before using this product, read this operator’s manual completely and familiarize yourself thoroughly with the

product, its components. Recognize the potential hazards associated with its use.

!

This manual is related to the following products: