Specifications

Model

MDL200

MDL252

MDL305

MDL400

MDL505

MDL600

Input rat ing s

Input Voltage

0-80 V

0-80 V

0-500 V

0-80 V

0-500 V

0-80 V

Input Current

Low

0-4 A

0-3 A

0-3 A

0-6 A

0-3 A

0-12 A

High

0-40 A

0-20 A

0-20 A

0-60 A

0-30 A

0-120 A

Input Power

200 W

250 W

1

300 W

400 W

500 W

600 W

Channels

1

2

1

1

1

1

Minimum

Operating Voltage

Low

0.10 V at 4 A

0.15 V at 3 A

0.7 V at 3 A

0.15 V at 6 A

0.54 V at 3 A

0.18 V at 12 A

High

1 V at 40 A

1 V at 20 A

4.5 V at 20 A

1.5 V at 60 A

5.4 V at 30 A

1.8 V at 120 A

CV mode

Range

Low

0-18 V

High

0-80 V

0-80 V

0-500 V

0-80 V

0-500 V

0-80 V

Resolution

Low

1 mV

High

10 mV

Accuracy

Low

± (0.05 % + 0.02 % F.S.)

High

± (0.05 % + 0.025 % F.S.)

CC mode

Range

Low

0-4 A

0-3 A

0-3 A

0-6 A

0-3 A

0-12 A

High

0-40 A

0-20 A

0-20 A

0-60 A

0-30 A

0-120 A

Resolution

Low

0.1 mA

1 mA

0.1 mA

High

1 mA

10 mA

1 mA

Accuracy

Low

± (0.05 % + 0.05 % F.S.)

± (0.05 % + 0.1 % F.S.)

High

± (0.05 % + 0.05 % F.S.)

± (0.1 % + 0.1 % F.S.)

CR mode

Range

Low

0.05 Ω-10 Ω

0.05 Ω-10 Ω

0.25 Ω-10 Ω

0.05 Ω-10 Ω

0.2 Ω-10 Ω

0.2 Ω-10 Ω

High

10 Ω-7.5 kΩ

Resolution

16-bit

Accuracy

Low

0.01 % + 0.08

S

High

0.01 % + 0.0008

S

CW mode

Range

200 W

250 W

300 W

400 W

500 W

600 W

Resolution

10 mW

Accuracy

± (0.2 % + 0.2 % F.S.)

Tran sien t mode (CC mode)

T1&T2

20 us-3600 s / Res: 5

µ

s-10 ms

Accuracy

5

µ

s+100 ppm

Slew Rate

2

Low

0.0001-0.25 A /

µ

s

0.0001-0.2 A /

µ

s

0.0001-0.1 A /

µ

s 0.0001-0.25 A /

µ

s 0.0001-0.1 A /

µ

s

0.0001-0.25 A /

µ

s

High

0.001-2.5 A /

µ

s

0.001-2 A /

µ

s

0.001-1 A /

µ

s

0.001-2.5 A /

µ

s

0.001-1 A /

µ

s

0.001-2.5 A /

µ

s

1 )

MDL252: The user can allocate up to 250 W to either channel up to 300 W total (e.g. 50 W/250 W, 250 W/50 W, 150 W/150 W).

2 )

The slew rate specifications are not warranted, but are descriptions of typical performance. The actual transition time is defined as the time for the input to change from 10% to 90%, or vice versa, of the

programmed current values. In case of very large load changes, e.g. from no load to full load, the actual transition time will be larger than the expected time. The load will automatically adjust the slew rate to fit
within the range (high or low) that is closest to the programmed value.