Neff D99L11N0 User Manual
Page 14
14
3. Insert 2 securing elements and screw tight.
4. Push lue duct upwards until it clicks into
position.
5. Insert metal-mesh grease ilter.
Installation
Locking screws and locking caps
1. Mark the holes for the safety screws.
Detach the extractor hood, drill holes for
the safety screws and press in wall plugs
lush with the wall.
2. Attach the extractor hood and screw in
the safety screws tightly.
3. Press the safety caps with the arrow
upwards onto the brackets until they click
into position
Ⓒ
.
ṇ
RISK OF INJURY
Check that all locking screws and locking
caps have been attached securely!
4. Connect the pipes
(see ”Connecting pipes”).
5. Connect to the power supply
(see ”Electrical connection”).
Removing the safety caps
Remove the locking caps from the brackets
using a suitable tool, e.g. a lat-blade
screwdriver.
Circulating air module
1. Place the circulating air module on the air
connection and screw tight.
2. Insert the activated-carbon ilters.
Installing the lue ducts
ṇ
RISK OF INJURY
The insides of the lue ducts may have sharp
edges. We recommend wearing protective
gloves during installation.
1. Remove the protective ilm from both
lue ducts.
2. Insert lue into the guide rails and slide
down.
2x
C
1
1
2
2x
2x