5.1 RS232 Configuration Overview

Baud Rate

9600 bps

Parity Bits

none

Data Bits

8

Start Bits

1

Stop Bits

1

Flow Control

Xon / Xoff

Termination Character

\r

Table 1 - RS232 Configuration

5.2 RS232 Commands

1.VOLT xx.xx

This command sets the output voltage value. The output voltage takes the
programmed value only if the power supply is in Constant Voltage mode.

Example: The output voltage is set at 5 V.

VOLT 05.00

2. CURR x.xxx

This command sets the output current value. The output current takes the
programmed value only if the power supply is in Constant Current mode.

Example: The output current is set at 300 mA.

CURR 0.300