beautypg.com

Neff D99L10N0 User Manual

Page 15

background image

15

Installation

The extractor hood is designed to be
mounted on the wall.

During installation, optional accessories may

also require itting.

Observe the minimum distance between

hob and extractor hood (see “Safety
instructions”)!

Avoid damaging the sensitive surfaces!

Preparing the wall

RISK OF INJURY,

DAMAGE TO PROPERTY

Before drilling the holes for the designated
installation location, check for concealed
electrical cables and other lines.

The wall must be level and vertical.

The enclosed screws and wall plugs are

suitable for solid brickwork. Use the appropriate
ixing materials for other wall structures (e.g.
plaster board, porous concrete, poroton bricks).
Ensure that the wall has adequate load
bearing capacity.

Ensure that the depth of the drilled holes

corresponds with the length of the screws.

Ensure that the wall plugs are secure.

Max. weight in kg: 55

Design subject to modiication in line with
technical development.

Installation preparations

1. Using the enclosed template, mark positions

for the screws and, to facilitate attachment,
the contour of the attachment area. The
lower edge of the template corresponds to
the lower edge of the extractor hood.

2. Drill 2x 8 mm Ø holes for suspension of the

extractor hood and press in wall plugs lush
with the wall.

3. Screw on the brackets for the extractor

hood: hand tight, max. 3 Nm
Ensure that the washers and brackets are
positioned correctly!

Attachment and alignment

1. Mount the extractor hood, ensuring that the

back is attached firmly to the brackets

.

2. Align the extractor hood horizontally by

turning the brackets.
If required, the extractor hood can be
moved to the right or left

.

10

983

209

2x

A

B

Locking screws and locking caps

1. Mark the holes for the safety screws.

Detach the extractor hood, drill holes for
the safety screws and press in wall plugs
lush with the wall.

2. Attach the extractor hood and screw in

the safety screws tightly.

3. Press the safety caps with the arrow

upwards onto the brackets until they
click into position

.

RISK OF INJURY

Check that all locking screws and locking
caps have been attached securely!
4. Connect the pipes

(see “Connecting pipes”).

5. Connect to the power supply

(see “Electrical connection”).

Removing the safety caps

Remove the locking caps from the

brackets using a suitable tool, e.g. a lat-
blade screwdriver.

2x

C