Total power solutions, Required, Xm2 “master” xm2 – Alpha Technologies XP-DSM Front Panel User Manual
Page 2: Make battery sense wire kit connections, Test the connection, Rf cable to headend, Member of the group
Total Power Solutions
Connections
Connections with more
than one power supply
RF Cable
to Headend
! Required
Grounded Surge Protector
(Alpha P/N 162-028-10 or equivalent)
Battery
nput
Temp
Probe
Battery
Breaker
STAT
ALM
RDY
COM
LNK
DS
REG
RF
DC
TMPR
O
O
C
O
M
S
Y
S
C
O
M
S
Y
S
XM2
XM2
“Master”
XM2
Generator (ECM)
(requires additional firmware,
contact Alpha for details)
ECM to SCM Interface
(Alpha P/N 704-709-20)
Battery String
Connectors
Communications
Port
System Port
Communications Port
System Port
Communications
Port
ALM
RDY
COM
LNK
RF
REG
DS
TMPR
CTRL
C
O
M
E
T
H
C
D
A
B
L
O
C
A
L
STAT
To Battery Sense Wire Harnesses
Environment Control Wire
(Alpha P/N 875-627-20) to Heater Mat, Fan, etc.
Serial Interface Card
(P/N 704-742-20)
Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2007 Alpha Technologies. All Rights Reserved. Alpha
®
is a registered trademark of Alpha Technologies. member of The Alpha Group™ is a trademark of Alpha Technologies.
745-814-B2-002 Rev. B (12/2007) To report errors or omissions in this document, send email to [email protected]
For more information visit www.alpha.com
United States
Bellingham, Washington Tel: 360 647 2360 Fax: 360 671 4936
Canada
Burnaby, British Columbia Tel: 604 436 5900 Fax: 604 436 1233
member of The Group
TM
4. Connect the RF drop and make front panel connections.
5. Initial Start-up and Test
• Plug the power supply into the AC outlet and turn on the battery breaker.
• The XP-DSM LEDs blink three times and the RDY light begins blinking
on and off.
• Verify no alarms are active.
• Verify the DS and REG LEDs are on solid. This verifies that the XP-DSM
has registered an IP address on the public network.
• Verify LNK LED is ON solid.
page 2 of 2
3. Make battery Sense Wire Kit connections.
See the battery diagrams that came with the sense wire kit or reference the XP-DSM Technical Manual.
The recommended downstream RF level is 0 dBmV, but can be anywhere in the DOCSIS range (+/- 15dBmV).
®
6. Test the Connection
Check the connection using a personal computer and a Local Port Adapter
Cable (Alpha Alpha P/N 745-826-21). Terminal Emulation software is necessary
(HyperTerminal is recommended). Serial communication settings are:
Baud:
19200 Data Bits: 8 Parity: None Stop Bits: 1 Flow Control: None
1.
Launch the terminal emulation software and hit ENTER to display the
menu of CIB tables.
2. Enter >tex and hit ENTER to display the contents of the TEXT table.
3. Check to see that CM IP is populated with the cable modem’s IP address
and CM/RF ENET with the RF MAC Address. If in Dual IP Mode, check
that IP ADDR IN USE is populated with the CPE IP address and ENET
ADDR with the CPE MAC Address. See the example to the right.
>tex
TEXT
----------------------------------------------
0 [ro] DHCP STATE
:
DISCOVER SENT
1 [ro] DHCP TIMER
:
0
2 [ro] DHCP SERV
:
0.0.0.0
3 [ro] DHCP SERV 54
:
0.0.0.0
4 [ro] DOWN STAT
:
5 [rw] DOWN NAME 1
:
6 [rw] DOWN NAME 2
:
7 [rw] DOWN IP
:
0.0.0.0
8 [rw] DOWN CFG
:
9 [rw] DOWN CFG IP
:
0.0.0.0
10 [rw] NTP SERV
:
0.0.0.0
11 [ro] NTP DHCP
:
0.0.0.0
12 [ro] NTP TIME UTC
:
01/01/70 00:00:00
13 [ro] ENET ADDR
:
00.90.EA.A0.1E.5F
14 [ro] IP ADDR IN USE
:
65.66.67.68
15 [ro] NETMASK IN USE
:
0.0.0.0
16 [ro] GATEWAY IN USE
:
0.0.0.0
17 [rw] IP ADDR STATIC
:
0.0.0.0
18 [rw] NETMASK STATIC :
0.0.0.0
19 [rw] GATEWAY STATIC
:
0.0.0.0
20 [rw] SNMP TRAP TARGET :
0.0.0.0
21 [rw] SNMP TRAP TARGET :
0.0.0.0
22 [rw] SNMP TRAP TARGET :
0.0.0.0
23 [rw] SNMP TRAP TARGET :
0.0.0.0
24 [rw] SNMP ACCESS LIST :
0.0.0.0
25 [rw] SNMP ACCESS LIST :
0.0.0.0
26 [rw] SNMP ACCESS LIST :
0.0.0.0
27 [rw] SNMP ACCESS LIST :
0.0.0.0
28 [ro] sysDescr
:
ATI P01V1.08.0
29 [rw] sysName
:
30 [rw] sysContact
:
31 [rw] sysLocation
:
32 [rw] comLogicalID
:
33 [ro] CHECK CODE
:
146.51.132.199
34 [rw] PING IP
:
0.0.0.0
35 [rw] ATICONFIG IP
:
0.0.0.0
36 [rw] ATICONFIG NAME
:
37 [ro] TIME UP
:
0 00:00:29
38 [ro] CM/RF ENET
:
00.03.08.0B.9A.EA
39 [ro] CM IP
:
10.20.30.40
40 [ro] CM SUBNET
:
255.255.255.0
41 [ro] CM GATEWAY
:
192.168.1.1
42 [ro] CM TOD
:
192.43.244.18
43 [ro] CM TFTP
:
192.168.1.51
44 [rw] SNMP GET
:
AlphaGet
45 [rw] SNMP SET
:
AlphaSet
46 [rw] SNMP TRAP
:
public
47 [rw] ALPHA SNMP SETS :
CIBSET
---------------------------------------------