34




COMMUNICATION


CAMERA ID

001

BAUD RATE

9600

PARITY

NONE


DEFAULT
RETURN>


Function

Description

CAMERA ID

Setting for the RS-485 camera ID (ID 0 is reserved for the control
unit)

BAUD RATE

Setting for the baud rate of the RS-485 communication interface.

PARITY

Setting for the parity of the communication interface.

DEFAULT

Restores all values in the sub-menu to the factory settings

RETURN

Back to main menu


Function

Description

BLOCK DISP

ON: When the video image content changes, the corresponding
points are marked with square blocks.
OFF: Block display is deactivated

DETECT SENSE

Sensitivity of the image change detection A higher value
increases the sensitivity

DURATION

Set delay time for the zoom factor (5, 10, 15, 20, 30 seconds, 1, 2,
3,4 or 5 minutes)

ALARM OUT

ON: Switching output is activated for successful motion detection.
OFF: Switching output is not activated for successful motion
detection.

ZOOM RATIO

Zoom factor which is set by the camera automatically for
successful motion detection.

DEFAULT

Restores all values in the sub-menu to the factory settings

RETURN