11
4-3-5
Accessibility to Motorized cartridge:
The motorized cartridge can be accessed through the access opening or removal of the main cover.
1)
Removal of power cartridge through the access opening:
Once the access cover has been removed and the basket is slid towards the opening, the four
fasteners securing the basket can be unscrewed. The basket can then be removed through the
opening followed by the power cartridge.
2)
Removal of power cartridge by disassembly of macerator:
If a ball valve was installed in the discharge line, it should be closed to eliminate the possibility of
waste discharging from the discharge pipe. Next, the discharge and vent flanges should be separated
from the main cover by removing 4 screws from each. The main cover can then be detached from the
tank by removing the fasteners on the periphery of the tank. The main cover can then be lifted
upward exposing the power cartridge.
Screw
Base
Utility blade
Cap
To remove cap
Unscrew
fastener
Place Allen
wrench
in hole to prevent
cutter from
turning
Cutting and health hazard,
caution must be used when