CONTROL BOXES
OM−04461
OPERATION
PAGE C − 2
breakers. The motor will not restart until the
circuit breakers are reset.
NOTE
If the circuit breaker trips, do not reset it immedi-
ately. Wait at least ten minutes before resetting the
control handle back to the ON position. If the over-
load unit continues to trip, operational problems ex-
ist. See TROUBLESHOOTING.
Always terminate incoming power to the control
box before investigating control box circuitry prob-
lems.
Always terminate power to the control
box before performing service func-
tions.
Power through the control box may be terminated
by moving the control handle to the OFF position,
thereby opening the circuit breakers. This stops
the pump, but does not terminate incoming power
through the field wiring connected to the control
box.
- SM4G1-X30 575/3 1002211 thru 1241783 SM4J1-X60 460/3 1004954 thru 1241784 SM4D18-X10 460/3 All serial numbers SM2E1-X3.5 460/3 All serial numbers Control Box SM2E1-X3.5 575/3 All serial numbers Control Box SM2E18-X3.5 460/3 All serial numbers Control Box SM2E18-X3.5 575/3 All serial numbers Control Box SM2E65-X3.5 460/3 All serial numbers Control Box SM2E65-X3.5 575/3 All serial numbers Control Box SM2F1-X1 460/3 All serial numbers Control Box SM2F1-X1 575/3 All serial numbers Control Box SM3B1-X6 460/3 All serial numbers Control Box