Gorman-Rupp Pumps SM4G1-X30 460/3 1002211 thru 1241783 User Manual
Page 11
OM−04461
CONTROL BOXES
PAGE B − 6
INSTALLATION
Figure B-3. Pump Power Cable Connection Diagram (All Models)
Power Cable Connection Instructions
1. Run the pump cable through the packing
gland nuts and washers (the concave side of
the washer should be towards the packing) at
the bottom of the control.
2. Connect the white, black and red power leads
to the terminals T1", T2", and T3", respec-
tively.
3. Connect the green ground lead to the termi-
nal GRD".
4. Connect the yellow ground check lead to the
terminal GC".
5. Connect the blue control lead to the terminal
P1".
6. Connect the orange control lead to the termi-
nal P2".
7. Install the packing in the gland with the wash-
ers on each side, and tighten the packing
gland nut. With the nuts tight and the packing
fully compressed, there must be a minimum
space of 1/8 inch between the bottom of the
nut and the enclosure.
9. Use the seal wire (P/N 31311-004) and lead
seal (P/N 21188-002) to secure the packing
gland nut to the enclosure. Use the hole in the
hex nut and the hole at the top left of the enclo-
sure to prevent loosening of the nut. See Ter-
minal Housing And Power Cable Reass-
embly And Installation in Section E for de-
tails.
Control Box Specifications
Overload relays are provided to protect the pump
motor.
If burnout of the overload protection oc-
curs, the complete overload protection
must be replaced.
- SM4G1-X30 575/3 1002211 thru 1241783 SM4J1-X60 460/3 1004954 thru 1241784 SM4D18-X10 460/3 All serial numbers SM2E1-X3.5 460/3 All serial numbers Control Box SM2E1-X3.5 575/3 All serial numbers Control Box SM2E18-X3.5 460/3 All serial numbers Control Box SM2E18-X3.5 575/3 All serial numbers Control Box SM2E65-X3.5 460/3 All serial numbers Control Box SM2E65-X3.5 575/3 All serial numbers Control Box SM2F1-X1 460/3 All serial numbers Control Box SM2F1-X1 575/3 All serial numbers Control Box SM3B1-X6 460/3 All serial numbers Control Box