S SERIES PUMPS

OM-06258

MAINTENANCE AND REPAIR

PAGE E - 20

terial has been noticeably compressed, it should
be supplemented with two gaskets contained in
the overhaul gasket kit (see Options listed in the
Parts List manual).

NOTE

Clean the cable leads and terminal plate in the ar­
eas to be sealed with cleaning solvent. Incomplete
sealing will occur if the surfaces are dirt, oil or
grease coated.

Assemble the terminal posts (1), dyna seal wash­
ers (20 ), and terminal collars (2) to the terminal
plate as shown in Figure E-2.

NOTE

Both the power cable and motor conductor leads
should be tinned prior to reassembly.

Slide a length of heat‐shrink tubing (3) up over
each of the power cable leads. Insert the leads in
the terminal collars and secure them using the al­
len head setscrews (18). Slide the tubing down
each lead until the terminals are covered and the
tubing contacts the terminal plate. The tubing
must extend up the leads far enough to ensure a
good seal.

Carefully heat each tube with a commercially avail­
able hot air gun capable of producing 750

_F

(399

_C), and shrink the tubes around the cable

leads and terminal collars.

Use only Dow‐Corning 737 Silicone Adhe­
sive (see the Parts List for the part number)
or potting compound for sealing terminal

housing connections. Use of unapproved
sealing products will void the pump war­
ranty.

NOTE

Do not use a mold or reservoir with the silicone
adhesive.

Silicone Sealant

Figure E-5. Silicone Adhesive Sealing

See Figure E-6 and check terminal locations. Ap­
ply a 1/4 to 3/8 in. (6,4 to 9,7 mm) thick layer (maxi­
mum) of silicone adhesive around each of the ter­
minal posts as shown in Figure E-5. Remove any
adhesive from gasketed surfaces.

All air pockets, voids or gaps in the sili­
cone sealant must be removed to en­
sure a water‐tight seal in the terminal
housing. Otherwise, moisture entering
the terminal housing could cause a
short circuit, resulting in pump damage
and possible serious injury or death to
personnel.

Allow the adhesive to cure for at least 24 hours in
open air
before securing the terminal housing to
the motor housing.