Gorman-Rupp Pumps S8A1-E95 575/3 1429751 and up User Manual
Page 46
S SERIES PUMPS
OM-06258
MAINTENANCE AND REPAIR
PAGE E - 20
terial has been noticeably compressed, it should
be supplemented with two gaskets contained in
the overhaul gasket kit (see Options listed in the
Parts List manual).
NOTE
Clean the cable leads and terminal plate in the ar
eas to be sealed with cleaning solvent. Incomplete
sealing will occur if the surfaces are dirt, oil or
grease coated.
Assemble the terminal posts (1), dyna seal wash
ers (20 ), and terminal collars (2) to the terminal
plate as shown in Figure E-2.
NOTE
Both the power cable and motor conductor leads
should be tinned prior to reassembly.
Slide a length of heat‐shrink tubing (3) up over
each of the power cable leads. Insert the leads in
the terminal collars and secure them using the al
len head setscrews (18). Slide the tubing down
each lead until the terminals are covered and the
tubing contacts the terminal plate. The tubing
must extend up the leads far enough to ensure a
good seal.
Carefully heat each tube with a commercially avail
able hot air gun capable of producing 750
_F
(399
_C), and shrink the tubes around the cable
leads and terminal collars.
Use only Dow‐Corning 737 Silicone Adhe
sive (see the Parts List for the part number)
or potting compound for sealing terminal
housing connections. Use of unapproved
sealing products will void the pump war
ranty.
NOTE
Do not use a mold or reservoir with the silicone
adhesive.
Silicone Sealant
Figure E-5. Silicone Adhesive Sealing
See Figure E-6 and check terminal locations. Ap
ply a 1/4 to 3/8 in. (6,4 to 9,7 mm) thick layer (maxi
mum) of silicone adhesive around each of the ter
minal posts as shown in Figure E-5. Remove any
adhesive from gasketed surfaces.
All air pockets, voids or gaps in the sili
cone sealant must be removed to en
sure a water‐tight seal in the terminal
housing. Otherwise, moisture entering
the terminal housing could cause a
short circuit, resulting in pump damage
and possible serious injury or death to
personnel.
Allow the adhesive to cure for at least 24 hours in
open air before securing the terminal housing to
the motor housing.