Gorman-Rupp Pumps S6A1-E60 460/3 1401314 and up User Manual
Page 40
S SERIES PUMPS
OM-06111
MAINTENANCE AND REPAIR
PAGE E - 14
strongly recommended that the bearings
be replaced any time the shaft and rotor
assembly is removed.
Before removing the bearings from the rotor shaft,
clean and inspect the bearings in place as follows.
Clean the bearings thoroughly in fresh cleaning
solvent. Dry the bearings with filtered compressed
air and coat with light oil.
Most cleaning solvents are toxic and
flammable. Use them only in a well ven
tilated area; free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain
ers.
Rotate the bearings by hand to check for rough
ness or binding and inspect the bearing balls. If ro
tation is rough or the bearing balls discolored, re
place the bearings.
The bearing tolerances provide a tight press fit
onto the shaft and a snug slip fit into the motor
housing and bearing bore. Replace the shaft and
rotor (as an assembly), the motor housing or inter
mediate if the proper bearing fit is not achieved.
If replacement is required, use a bearing puller to
remove the upper and lower ball bearings from the
rotor shaft. Remove the bearing cap (38) and gas
ket (39) from the rotor shaft.
NOTE
It may be necessary to use the bearing cap (38) and
capscrews (44) in conjunction with a bearing puller
to remove the lower bearing.
Stator Removal
(Figure E-1)
Do not remove the stator (35) unless it is defective
(open windings, insulation resistance low, or stator
core damaged). If the stator must be removed, re
move the terminal housing as indicated in Termi
nal Housing And Power Cable Disassembly.
Position an expandable tool, such as a split disc,
approximately 2 inches (51 mm) inside the stator,
and expand it tightly and squarely on the I.D. At
tach a lifting device to the lifting eye of the tool, and
raise the assembly approximately 1 inch (25 mm)
off the work surface.
The motor housing (18) must be heated with a
torch to expand it enough for the stator to be re
moved. Apply heat evenly to the outside of the mo
tor housing; excessive heat is not required. Use a
soft‐faced mallet to rap alternate edges of the mo
tor housing, and “walk” the stator out. Continue
this process until the stator clears the motor hous
ing.
Take care not to damage the stator end
turns during removal from the motor hous
ing.
After the stator has been removed, wrap it in clean,
dry rags or other suitable material until reassembly.
The stator must be kept clean and dry. When han
dling the stator, do not set it on the end windings;
lay it on its side.
Do not attempt to rewind the stator. Wind
ing tolerances and materials are closely
controlled by the manufacturer, and any
deviation can cause damage or operating
problems. Replace the stator, or return it to
one of The Gorman‐Rupp Authorized Sub
mersible Repair Centers or The Gorman‐
Rupp factory, if defective.
Relief Valve
(Figure E-1)
It is recommended that the pressure relief valve
(25) be replaced at each overhaul, or at any time
the pump motor overheats and activates the valve.
Never replace this valve with a substitute which has
not been specified or provided by the Gorman‐
Rupp Company.
It is not necessary to remove the heavy pipe nipple
(26) to remove the pressure relief valve. If the nip