Gorman-Rupp Pumps S6A1-E60 460/3 1401314 and up User Manual
Page 19
S SERIES PUMPS
OM-06111
PAGE C - 3
OPERATION
this pump is high enough to cause inju
ry or death. Make certain that incoming
power is off and locked out before inter
changing motor leads.
DIRECTION OF
KICKBACK
AT STARTUP
Figure C-1. Checking Pump Rotation
STARTING, STOPPING, AND
OPERATIONAL CHECKS
Starting
Do not attempt to operate the pump until
impeller rotation has been checked; im
proper rotation will affect pump perform
ance and may damage the pump.
Follow the instructions accompanying the control
box, start the pump, and run any recommended
checks.
Never start the pump more than 6 times per
hour. If the pump motor does not cool be
tween starts, it will over‐heat, resulting in
damage to the motor windings.
Stopping
Follow the instructions accompanying the control
box for stopping the pump.
On pumps equipped with a motor ther
mal protector, the integral thermal over
load device will shut off the motor if the
temperature rises above design limits.
When the pump cools and the tempera
ture falls below these limits, the motor
will restart automatically. To avoid the
hazards of an unexpected motor start‐
up, do not attempt to handle or service
the pump unless all power to the motor
has been shut off and locked out at the
control box; otherwise, serious person
al injury could result.
During motor shutoff by the thermal
overload device, control box circuits re
main live. Do not attempt to service any
control box components unless incom
ing power has been shut off.
To stop the pump, turn the control handle OFF,
thereby opening the circuit breakers. This does
not terminate incoming power through the field
wiring connected to the control box.
After stopping the pump, be sure to perform all re
quired maintenance and preservation procedures.
Operational Checks
To detect minor problems, check the pump for
proper operation when it is first started, and at peri
odic intervals during operation.