TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO
START, OVERLOAD
UNIT NOT TRIPPED
(MANUAL MODE)
OVERLOAD UNIT
TRIPS
PA SERIES
OM-06531
TROUBLESHOOTING
PAGE D - 3
Pump Troubleshooting (Cont'd)
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
BEARINGS RUN
TOO HOT
Bearing temperature is high, but
within limits.
Align drive properly.
Drive misaligned.
Check piping installation for proper
support.
Suction and discharge lines not prop
erly supported.
Check for proper type and level of
lubricant.
Low or incorrect lubricant.
Check bearing temperature regu
larly to monitor any increase.
Check belt tension. Adjust as
required.
Excessive tension on drive belt.
Control Box Troubleshooting
Power source incompatible with control
Correct power source.
box.
No voltage at line side of circuit beaker.
Check power source for blown fuse,
open overload unit, broken lead, or
loose connection.
No voltage at line terminals on bottom
Check power source for blown fuse,
of overload unit in control box.
open disconnect, broken wire, or
loose connection.
Low or high voltage, or excessive volt‐
Measure voltage at control box.
age drop between pump and control
Check that wiring is correct type, size,
box.
and length. (See Field Wiring
Connections,Section B).
Power input phases not
If imbalance exceeds 1 percent,
balanced.
notify power company
Control box not compatible with pump.
Electrical data on control box and
pump name plate must agree. Re‐
place control box if not in agreement.
Foreign object locking impeller or
Remove foreign material or replace
bearing frozen.
damaged bearing. If bearing is
damaged, check for water in motor
housing.
Motor windings short‐circuited.
Check motor windings with
ohmmeter.