beautypg.com

Gorman-Rupp Pumps PA6C60C-B-E50 460/3 1528569 and up User Manual

Page 13

background image

PA SERIES

OM-06531

PAGE B - 5

INSTALLATION

Figure 2. Recommended Minimum Suction Line Submergence vs. Velocity

DISCHARGE LINES

Siphoning

Do not terminate the discharge line at a level lower
than that of the liquid being pumped unless a si­
phon breaker is used in the line. Otherwise, a si­
phoning action causing damage to the pump
could result.

Valves

This pump is designed with a check valve in the
discharge line.

If a throttling valve is desired in the discharge line,
use a valve as large as the largest pipe to minimize
friction losses. Never install a throttling valve in a
suction line.

With high discharge heads, it is recommended that
a throttling valve be installed in the discharge line
to protect the pump from excessive shock pres­
sure and reverse rotation when it is stopped.

If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.

ELECTRICAL CONNECTIONS

Obtain the services of a qualified elec­
trician to make all electrical connec­
tions and to service the control box.

The electrical power used in this control
box is high enough to cause injury or
death. Make certain that the control box
is properly grounded after installation.
Make certain that the power source
phase and voltage matches the data on