TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO
PRIME
Strainer clogged.
Check strainer and clean if neces
sary.
Suction lift or discharge head too high.
Check piping installation and install
bypass line if needed. See INSTAL
LATION.
Leaking or worn seal or pump gasket.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Lining of suction hose collapsed.
Replace suction hose.
Air leak in suction line.
Correct leak.
Discharge check valve contami
nated, damaged, or unable to seat.
Clean or replace check valve.
PUMP STOPS OR
FAILS TO DELIVER
RATED FLOW OR
PRESSURE
Air leak in suction line.
Correct leak.
Lining of suction hose collapsed.
Replace suction hose.
Leaking or worn seal or pump gasket.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Air compressor damaged/belts broken.
Check and repair/replace.
Eductor clogged.
Check and clean eductor.
PA SERIES
OM-06531
TROUBLESHOOTING
PAGE D - 1
TROUBLESHOOTING - SECTION D
Review all SAFETY information in Section A.
The following information is divided into two cate
gories; Pump Troubleshooting and Control Box
Troubleshooting. Additionally, there is a Pump Pre
ventive Maintenance Schedule at the end of this
section. Refer to the appropriate chart for possible
causes and remedies for your specific problem.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Turn the control box selector
switch to `OFF' and lock it out to en
sure that the pump will remain in
operative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
This pump may be equipped with an op
tional automatic starting system, and
therefore subject to automatic restart.
Keep hands and clothing away from the
unit to prevent injury during automatic
operation. Disconnect the positive bat
tery cable before performing any main
tenance. Failure to do so may result in
serious personal injury.
Obtain the services of a qualified elec
trician to troubleshoot, test and/or ser
vice the electrical components of the
control box.
Pump Troubleshooting