background image

OM-06199

PA SERIES

MAINTENANCE & REPAIR

PAGE E - 25

LUBRICATION

(Figure 4)

Seal Assembly

Fill the seal cavity through the hole for the vented
plug (14) with SAE No. 30 non‐detergent oil. Check
the oil level regularly and refill as required. When lu­
bricating a dry seal cavity, add approximately
approximately 256 oz. or 8 U.S. quarts (7,6 liters) of
oil to level indicated.

Bearings

(Figure 5)

The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu­
larly through the sight gauges (5)

and maintain it at

the midpoint of the gauge. When lubrication is re­
quired, remove the air vent and bushing (9 and 10)
and add SAE No. 30 non‐detergent oil through the
opening. When lubricating a dry (overhauled)
bearing housing, fill the bearing cavity with approx­
imately 40 ounces (1,2 liters) of oil. Clean and rein­
stall the air vent. Do not over‐lubricate. Over‐lubri­
cation can cause the bearings to over‐heat, result­
ing in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous­
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con­
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Engine

Consult the literature supplied with the engine, or
contact your local engine representative.