beautypg.com

Troubleshooting - section d – Gorman-Rupp Pumps PA6C60-4045T 1481445 thru 1254713 User Manual

Page 17

background image

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP FAILS TO
PRIME

Strainer clogged.

Check strainer and clean if neces­
sary.

Suction lift or discharge head too high.

Check piping installation and install
bypass line if needed. See INSTAL­
LATION
.

Leaking or worn seal or pump gasket.

Check pump vacuum. Replace

leaking or worn seal or gasket.

Lining of suction hose collapsed.

Replace suction hose.

Air leak in suction line.

Correct leak.

Discharge check valve contami­
nated, damaged, or unable to seat.

Clean or replace check valve.

PUMP STOPS OR
FAILS TO DELIVER
RATED FLOW OR
PRESSURE

Air leak in suction line.

Correct leak.

Lining of suction hose collapsed.

Replace suction hose.

Leaking or worn seal or pump gasket.

Check pump vacuum. Replace

leaking or worn seal or gasket.

Air compressor head 180

_ out.

Consult factory.

Air compressor damaged or belts bro­
ken.

Check and repair/replace.

Eductor clogged.

Check and clean eductor.

PA SERIES

OM-06199

TROUBLESHOOTING

PAGE D - 1

TROUBLESHOOTING - SECTION D

Review all SAFETY information in Section A.

Before attempting to open or service the
pump:
1. Familiarize yourself with this manual.
2. Shut down the engine, disconnect

the positive battery cable and take
precautions to ensure that the pump
will remain inoperative.

3. Allow the pump to completely cool if

overheated.

4. Check the temperature and make

sure pump is cool before opening
any covers, plates, or plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cautiously.
7. Drain the pump.