Gorman-Rupp Pumps PA6C60C-F4L 1504811 and up User Manual
Page 20
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP STOPS OR
FAILS TO DELIVER
RATED FLOW OR
PRESSURE (cont.)
PUMP REQUIRES
TOO MUCH
POWER
PUMP CLOGS
FREQUENTLY
Impeller or other wearing parts worn
or damaged.
Free impeller of debris.
Impeller clogged.
Replace worn or damaged parts.
Check that impeller is properly
centered and rotates freely.
Discharge head too high.
Measure lift w/vacuum gauge. Re
duce lift and/or friction losses in
suction line.
Suction lift too high.
Install bypass line.
Pump speed too slow.
Check engine output; consult en
gine operation manual.
Pump speed too high.
Check engine output.
Discharge head too low.
Dilute if possible.
Liquid solution too thick.
Adjust discharge valve.
Pump or jack shaft bearing(s) frozen.
Disassemble, check and replace
bearing(s) as required..
Liquid solution too thick.
Open discharge valve fully to in
crease flow rate, and run engine at
maximum governed speed.
Discharge flow too slow.
Dilute if possible.
Suction check valve or foot valve
clogged or binding.
Clean valve.
Suction intake not submerged at
proper level or sump too small.
Check installation and correct
submergence as needed.
EXCESSIVE NOISE
Cavitation in pump.
Reduce suction lift and/or friction
losses in suction line. Record vac
uum and pressure gauge readings
and consult local representative or
factory.
Clean out debris; replace damaged
parts.
Impeller clogged or damaged.
Secure mounting hardware.
Pump or drive not securely mounted.
Locate and eliminate source of air
bubble.
Pumping entrained air.
Discharge check valve clogged.
Check and clean check valve.
Strainer clogged.
Check strainer and clean if neces
sary.
Belt or flexible coupling broken.
Check and replace as necessary.
Extreme ambient temperature.
Reduce pump output.
Fuel filter clogged.
Check & replace often in extreme
operating conditions.
Check and replace as required.
Fuel contaminated.
OM-05768
PA SERIES
TROUBLESHOOTING
PAGE D - 2