PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY

Review all SAFETY information in Section A.

Follow the instructions on all tags, label and de­
cals attached to the pump.

This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be­
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the illustrations (see Figures 1 through 4) and the
corresponding Parts Lists. Maintenance and repair
instructions for the air compressor are covered
separately in specific literature available from the
manufacturer.

Before attempting to service the pump, lock out
and tag out incoming power to the control box and
take precautions to ensure that it will remain inop­
erative. Close all valves in the suction and dis­
charge lines and drain the pump casing by remov­
ing the casing drain plug (3, Figure 1). Clean and
reinstall the drain plug.

This manual will alert personnel to
known procedures which require spe­
cial attention, to those which could
damage equipment, and to those which
could be dangerous to personnel.

How­

ever, this manual cannot possibly antici­
pate and provide detailed instructions
and precautions for every situation that
might occur during maintenance of the
unit. Therefore, it is the responsibility of
the owner/maintenance personnel to
ensure that only safe, established main­
tenance procedures are used, and that
any procedures not addressed in this
manual are performed only after estab­
lishing that neither personal safety nor

pump integrity are compromised by
such practices.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man­

ual.

2. Disconnect or lock out the power

source to ensure that the pump will
remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature and make

sure it is cool before opening any
covers, plates, gauges, or plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau­

tiously.

7. Drain the pump.

This pump may be equipped with an op­
tional automatic starting system, and
therefore subject to automatic restart.
Keep hands and clothing away from the
unit to prevent injury during automatic
operation. Lock out the power from the
control box to ensure that the pump will
remain inoperative. Failure to do so
may result in serious personal injury.

Use only replacement parts provided or
approved by Gorman‐Rupp. Use of non‐
authorized parts may result in damage to
the equipment and/or injury to personnel
and will invalidate the warranty.