Operation - section c – Gorman-Rupp Pumps PAV3A60C-B 1511107 and up User Manual
Page 14
PA SERIES
OM-06525
OPERATION
PAGE C - 1
OPERATION - SECTION C
Review all SAFETY information in Section A.
Follow the instructions on all tags, labels and de
cals attached to the pump.
This pump is designed to handle most
non‐volatile, non‐flammable liquids
containing specified entrained solids.
Do not attempt to pump volatile, corro
sive, or flammable liquids which may
damage the pump or endanger person
nel as a result of pump failure.
Pump speed and operating conditions
must be within the performance range
shown on page E‐1.
STARTING
Install the pump and piping as described in IN
STALLATION. Make sure that the piping connec
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri
cated (see LUBRICATION in MAINTENANCE
AND REPAIR).
Consult the operations manual furnished with the
power source.
Rotation
The correct direction of pump rotation is counter
clockwise when facing the impeller. The pump
could be damaged and performance adversely af
fected by incorrect rotation. If pump performance
is not within the specified limits (see the curve on
page E‐1), check the direction of power source ro
tation before further troubleshooting.
If an electric motor is used to drive the pump, re
move V‐belts, couplings, or otherwise disconnect
the pump from the motor before checking motor
rotation. Operate the motor independently while
observing the direction of the motor shaft, or cool
ing fan.
If rotation is incorrect on a three‐phase motor, have
a qualified electrician interchange any two of the
three phase wires to change direction. If rotation is
incorrect on a single‐phase motor, consult the liter
ature supplied with the motor for specific instruc
tions.
PRIMING
The pump will begin to prime upon startup. The air
in the suction line will be discharged from the prim
ing chamber discharge line. Complete priming is
indicated by a positive discharge pressure read
ing.
If full priming is not achieved, the discharge check
valve may be malfunctioning. If this occurs, shut
down the pump and consult the Maintenance and
Repair section of this manual for further details.
OPERATION
Leakage
No leakage should be visible at pump mating sur
faces, or at pump connections or fittings. Keep all
line connections and fittings tight to maintain maxi
mum pump efficiency.
Liquid Temperature And Overheating
The maximum liquid temperature for this pump is
160
_F (71_C). Do not apply it at a higher operating
temperature.
Overheating can occur if operated with the valves
in the suction or discharge lines closed. Operating