beautypg.com

Gorman-Rupp Pumps PAH8A60C-B 1537579 and up User Manual

Page 12

background image

OM-06455

PAH SERIES

PAGE B - 4

INSTALLATION

Figure 1. Recommended Minimum Suction Line Submergence vs. Velocity

DISCHARGE LINES

Siphoning

Do not terminate the discharge line at a level lower
than that of the liquid being pumped unless a si­
phon breaker is used in the line. Otherwise, a si­
phoning action causing damage to the pump
could result.

Valves

This pump is designed with a check valve in the
discharge line.

If a throttling valve is desired in the discharge line,
use a valve as large as the largest pipe to minimize
friction losses. Never install a throttling valve in a
suction line.

With high discharge heads, it is recommended that
a throttling valve and a system check valve be in­
stalled in the discharge line to protect the pump
from excessive shock pressure and reverse rota­
tion when it is stopped.

If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.

ALIGNMENT

The alignment of the pump and its power source is
critical for trouble‐free mechanical operation. In
either a flexible coupling or V‐belt driven system,
the driver and pump must be mounted so that their
shafts are aligned with and parallel to each other. It
is imperative that alignment be checked after the
pump and piping are installed, and before opera­
tion.

NOTE

Check Rotation, Section C, before final alignment
of the pump.

When mounted at the Gorman‐Rupp factory, driver
and pump are aligned before shipment. Misalign­
ment will occur in transit and handling. Pumps