Pump maintenance and repair – Gorman-Rupp Pumps 4D-B 461594 and up User Manual
Page 15
D SERIES
OM--01505
MAINTENANCE & REPAIR
PAGE E -- 1
PUMP MAINTENANCE AND REPAIR - SECTION E
MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAK OPER-
ATING PERFORMANCE.
IN GALLONS PER MINUTE AT 52 STROKES PER MINUTE
STATIC
LIFT
IN FEET
STATIC DISCHARGE HEAD IN FEET
0
10
15
20
5
150
119
113
112
10
126
108
105
105
73
74
75
98
15
20
94
74
73
66
60
66
70
74
25
IN LITERS PER MINUTE AT 52 STROKES PER MINUTE
STATIC DISCHARGE HEAD IN METERS
STATIC
LIFT
IN METERS
0
3,0
4,6
6,1
1,5
567,8
450,4
427,7
423,9
3,0
476,9
408,8
397,4
397,4
4,6
370,9
283,8
280,1
276,3
6,1
355,8
280,1
276,3
249,8
7,6
280,1
264,9
249,8
227,1
7,6
393,6
378,5
264,9
238,4
196,8
1,5
473,1
446,6
367,1
310,3
310,3
25
104
100
70
63
52
5
125
118
97
82
82
STANDARD PERFORMANCE TEST DATA FOR PUMP MODEL 4D-B
Based on 70_ F (21_ C) clear water at sea level
with minimum suction lift, using 3 inch (7,62 cm)
suction hose and 4 inch (10,16 cm) non-collapsible
discharge hose. Since pump installations are sel-
dom identical, your performance may be different
due to such factors as viscosity, specific gravity,
elevation, temperature, and impeller trim.
If your pump serial number is followed by an “N”,
your pump is
NOT a standard production model.
Contact the Gorman-Rupp Company to verify per-
formance or part numbers.