Lubrication – Gorman-Rupp Pumps 66B2-B 370671 and up User Manual
Page 32
60 SERIES
OM−01454
MAINTENANCE & REPAIR
PAGE E − 10
The balance ring must seat squarely in the
casing bore or binding and/or excessive
wear will result.
Replace the suction cover gasket (39). Position the
suction cover over the studs (37) and secure the
suction head to the pump casing using the nuts
(38). Make sure the jacking screws (33) do not in-
terfere with the cover plate seating.
Turn the shaft by hand to make sure that the impel-
ler is not binding or scraping.
Final Pump Assembly
Be sure the pump assembly is securely mounted
to the power source and base.
Install the suction and discharge lines and open all
valves. Make certain that all piping connections are
tight, properly supported and secure.
Be sure the pump and power source have been
properly lubricated, see LUBRICATION.
Refer to OPERATION, Section C, before putting
the pump back into service.
LUBRICATION
Seal Assembly
Fill the grease cup (5) through the grease fitting
with No. 2 lithium base grease until grease es-
capes from the relief hole. Turn the grease cup arm
counterclockwise until it is at the top of the stem;
this will release the spring to apply grease to the
seal (see Figure 5).
GREASE
FITTING
CROSS
ARM
POSITION
WHEN
EMPTY
POSITION
FOR
FILLING
POSITION
WHEN
IN USE
RELIEF
HOLE
Figure 5. Automatic Lubricating Grease Cup
NOTE
Some smoking and leakage may occur after instal-
ling a new seal assembly. This should stop after the
pump has run a while and the lapped seal faces
have seated in.
Bearings
The pedestal was fully lubricated when shipped
from the factory. Under normal conditions, remove