beautypg.com

Gorman-Rupp Pumps 66B2-B 370671 and up User Manual

Page 19

background image

60 SERIES

OM−01454

OPERATION

PAGE C − 4

BEARING TEMPERATURE CHECK

Bearings normally run at higher than ambient tem-
peratures because of heat generated by friction.
Temperatures up to 160

_F (71,1_C) are consid-

ered normal for bearings, and they can operate
safely to at least 180

_F (82,2_C).

Checking bearing temperatures by hand is inaccu-
rate. Bearing temperatures can be measured ac-
curately by placing a contact-type thermometer
against the housing. Record this temperature for
future reference.

A sudden increase in bearing temperature is a
warning that the bearings are at the point of failing
to operate properly. Make certain that the bearing
lubricant is of the proper viscosity and at the cor-
rect level (see LUBRICATION in MAINTENANCE
AND REPAIR). Bearing overheating can also be
caused by shaft misalignment and/or excessive vi-
bration.

When pumps are first started, the bearings may
seem to run at temperatures above normal. Con-
tinued operation should bring the temperatures
down to normal levels.