PAGE E - 11
Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak
age. If any components are worn, replace the com
plete seal; never mix old and new seal parts.
If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter.
To ease installation of the seal, lubricate the shaft
sleeve O‐ring and the external stationary seat O‐
ring with a very small amount of light lubricating oil.
See Figure 5 for seal part identification.
SEAL PLATE
O‐RINGS
IMPELLER
OIL SEAL
STATIONARY
STATIONARY
ROTATING
DRIVE BAND
BELLOWS
IMPELLER SHIMS
IMPELLER
SPRING
RETAINER
ELEMENT
ELEMENT
SEAT
SHAFT
SHAFT SLEEVE
SLEEVE
O‐RING
SPRING
CENTERING
WASHER
Figure 5. 46513-154 Cartridge Seal Assembly
This seal is not designed for operation at
temperatures above 160
_
F (71
_
C). Do not
use at higher operating temperatures.
If the seal plate was removed, install the seal plate
gasket (6). Position the seal plate over the shaft
and secure it to the bearing housing with the hard
ware (8 and 9).
To prevent damaging the shaft sleeve O‐ring (4) on
the shaft threads, stretch the O‐ring over a piece of
tubing 1‐1/4 I.D. x 1‐1/2 O.D. x 2‐inches long (32
mm x 38 mm x 51 mm). Slide the tube over the shaft
threads, then slide the O‐ring off the tube and onto
the shaft. Remove the tube, and continue to slide
the O‐ring down the shaft until it seats against the
shaft shoulder.
When installing a new cartridge seal assembly,
remove the seal from the container, and remove
the mylar storage tabs, if so equipped, from be
tween the seal faces.
Most new cartridge seal assemblies are
equipped with mylar storage tabs between
the seal faces. These storage tabs must be