SUPER T SERIES
MAINTENANCE & REPAIR
PAGE E - 7
NOTE
An alternate method of removing the back cover
from the pump casing is to remove the back cover
nuts (13) and two diagonally opposing locking col
lars (12). Install two 1/2-13 UNC x 2 inch long
screws in the tapped holes in the back cover and
use them to press the back cover out of the pump
casing.
Inspect the wear plate and replace it if badly scored
or worn. To remove the wear plate, disengage the
hardware (7 and 8).
Inspect the back cover O‐rings (6 and 9) and re
place them if damaged or worn.
Suction Check Valve Removal
(Figure 1)
If the check valve assembly (23) is to be serviced,
remove the check valve pin (22), reach through the
back cover opening and pull the complete assem
bly from the suction flange (21).
NOTE
Further disassembly of the check valve is not re
quired since it must be replaced as a complete unit.
Individual parts are not sold separately.
Rotating Assembly Removal
(Figure 2)
The rotating assembly may be serviced without
disconnecting the suction or discharge piping;
however, the power source must be removed to
provide clearance.
The impeller (1) should be loosened while the rotat
ing assembly is still secured to the pump casing.
Before loosening the impeller, remove the seal cav
ity drain plug (16B) and drain the seal lubricant.
This will prevent the oil in the seal cavity from es
caping when the impeller is loosened. Clean and
reinstall the seal cavity drain plug.
Immobilize the impeller by wedging a block wood
between the vanes and the pump casing, and re
move the impeller capscrew and washer (26 and
27).
Install the shaft key (23). Install a lathe dog on the
drive end of the shaft (24) with the “V” notch posi
tioned over the shaft key.
With the impeller rotation still blocked, see Figure 3
and use a long piece of heavy bar stock to pry
against the arm of the lathe dog in a counterclock
wise direction (when facing the drive end of the
shaft). Use caution not to damage the shaft or key
way. When the impeller breaks loose, remove the
lathe dog, key and wood block.
NOTE
Do not remove the impeller until the rotating assem
bly has been removed from the pump casing.
Turn
Counterclockwise
Lathe Dog Arm
“V” Notch
Shaft Key
Impeller Shaft
Lathe Dog
Setscrew
Heavy
Bar Stock
Figure 3. Loosening Impeller
(Figure 1)
Remove the hardware (14 and 32) securing the ro
tating assembly to the pump casing. Separate the
rotating assembly by pulling straight away from the
pump casing. Retain the rotating assembly shims
(33).
NOTE
An optional disassembly tool is available from the
factory. If the tool is used, follow the instructions
packed with it. A similar tool may be assembled us
ing 1/2‐inch pipe (schedule 80 steel or malleable
iron) and a standard tee (see Figure 4). All threads
are 1/2‐inch NPT. Do not pre‐assemble the tool.