Gorman-Rupp Pumps T6A65S-B /F,/FM User Manual
Page 33
OM-05453
SUPER T SERIES
MAINTENANCE & REPAIR
PAGE E - 10
Heat the bearings to a uniform temperature no
higher than 250
_F (120_C), and slide the bearings
onto the shaft, one at a time, until they are fully
seated. This should be done quickly, in one con
tinuous motion, to prevent the bearings from cool
ing and sticking on the shaft.
After the bearings have been installed and allowed
to cool, check to ensure that they have not moved
away from the shaft shoulders in shrinking. If
movement has occurred, use a suitable sized
sleeve and a press to reposition the bearings
against the shaft shoulders.
If heating the bearings is not practical, use a suit
able sized sleeve, and an arbor (or hydraulic) press
to install the bearings on the shaft.
When installing the bearings onto the
shaft, never press or hit against the outer
race, balls, or ball cage. Press only on the
inner race.
Secure the outboard bearing on the shaft with the
bearing snap ring (14).
It is recommended that a sleeve be positioned
against the oil seal (18) to prevent the lip of the oil
seal from rolling as the shaft and bearings are
installed in the bearing housing. The O.D. of the
sleeve should be just smaller than the bearing
housing bore, while the I.D. of the sleeve should be
just larger than the O.D. of the lip seal area of the
shaft.
With the lip seal sleeve in place, lubricate the lip
seal area of the shaft, and slide the shaft and as
sembled bearings into the bearing housing until
the retaining ring on the outboard bearing seats
against the bearing housing. Remove the lip seal
sleeve.
When installing the shaft and bearings into
the bearing bore, push against the outer
race. Never hit the balls or ball cage.
Position the oil seal (19) on the lubricated shaft with
the lip positioned as shown in Figure 2. Press the
oil seal into the bearing housing until the face of the
seal is just flush with the machined surface on the
bearing housing.
Press the oil seal (13) into the bearing cap (10) with
the lip positioned as shown in Figure 2. Replace
the bearing cap gasket (17), and secure the bear
ing cap with the hardware (15 and 16). Be careful
not to damage the oil seal lip on the shaft keyway.
Lubricate the bearing housing as indicated in LU
BRICATION.
Seal Installation
(Figures 2 and 5)
Most cleaning solvents are toxic and
flammable. Use them only in a well ven
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain
ers.
Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent. Inspect the stationary
seat bore in the seal plate for dirt, nicks and burrs,
and remove any that exist. The stationary seat bore
must be completely clean before installing the
seal.
A new seal assembly should be installed
any time the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.
Reusing an old seal could result in prema
ture failure.
The seal is not normally reused because wear pat
terns on the finished faces cannot be realigned
during reassembly. This could result in premature
failure. If necessary to reuse an old seal in an emer
gency, carefully wash all metallic parts in fresh
cleaning solvent and allow to dry thoroughly.