Gorman-Rupp Pumps T6A65S-B /F,/FM User Manual
Page 21
OM-05453
SUPER T SERIES
TROUBLESHOOTING
PAGE D - 2
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP REQUIRES
TOO MUCH
POWER
PUMP CLOGS
FREQUENTLY
Impeller or other wearing parts worn
or damaged.
Replace worn or damaged parts.
Check that impeller is properly
centered and rotates freely.
Impeller clogged.
Free impeller of debris.
Pump speed too slow.
Check driver output; check belts
or couplings for slippage.
Discharge head too high.
Install bypass line.
Suction lift too high.
Measure lift w/vacuum gauge. Re
duce lift and/or friction losses in
suction line.
Pump speed too high.
Check driver output; check that
sheaves or couplings are cor
rectly sized.
Discharge head too low.
Adjust discharge valve.
Liquid solution too thick.
Dilute if possible.
Bearing(s) frozen.
Disassemble pump and check
bearing(s).
Liquid solution too thick.
Dilute if possible.
Discharge flow too slow.
Open discharge valve fully to in
crease flow rate, and run power
source at maximum governed
speed.
Suction check valve or foot valve
clogged or binding.
Clean valve.
PUMP STOPS OR
FAILS TO DELIVER
RATED FLOW OR
PRESSURE
Air leak in suction line.
Lining of suction hose collapsed.
Correct leak.
Replace suction hose.
Leaking or worn seal or pump gasket.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Strainer clogged.
Check strainer and clean if neces
sary.
Suction intake not submerged at
proper level or sump too small.
Check installation and correct sub
mergence as needed.