beautypg.com

Gorman-Rupp Pumps T10A3S-B /FM,/WW User Manual

Page 37

background image

OM-05290

SUPER T SERIES

MAINTENANCE & REPAIR

PAGE E - 16

Bearings

(Figure E‐2)

The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu­
larly through the sight gauge (30)

and maintain it at

the middle of the gauge. When lubrication is re­
quired, remove the air vent and bushing (11 and
12) and add SAE No. 30 non‐detergent

oil through

the hole until the level is at the middle of the sight
gauge. Do not over‐lubricate. Over‐lubrication can
cause the bearings to over‐heat, resulting in pre­
mature bearing failure.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous­
ing once each year and refill with approximately 27
ounces (0,8 liter) of clean oil. Change the oil more
frequently if the pump is operated continuously or
installed in an environment with rapid temperature
change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.