Gorman-Rupp Pumps T10A3S-B /FM,/WW User Manual
Page 37
OM-05290
SUPER T SERIES
MAINTENANCE & REPAIR
PAGE E - 16
Bearings
(Figure E‐2)
The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu
larly through the sight gauge (30)
and maintain it at
the middle of the gauge. When lubrication is re
quired, remove the air vent and bushing (11 and
12) and add SAE No. 30 non‐detergent
oil through
the hole until the level is at the middle of the sight
gauge. Do not over‐lubricate. Over‐lubrication can
cause the bearings to over‐heat, resulting in pre
mature bearing failure.
NOTE
The white reflector in the sight gauge must be posi
tioned horizontally to provide proper drainage.
Under normal conditions, drain the bearing hous
ing once each year and refill with approximately 27
ounces (0,8 liter) of clean oil. Change the oil more
frequently if the pump is operated continuously or
installed in an environment with rapid temperature
change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.