beautypg.com

Gorman-Rupp Pumps 82D2-B 344003 and up User Manual

Page 29

background image

OM−00802

80 SERIES

MAINTENANCE & REPAIR

PAGE E − 11

ously or installed in an environment where variable
hot and cold temperatures are common.

When lubricating a dry (overhauled) pedestal, fill
the cavity with approximately 1.5 ounces (43
grams) of grease.

Monitor the condition of the bearing lubri-

cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.

Power Source

Consult the literature supplied with the power
source, or contact your local power source repre-
sentative.