beautypg.com

Gorman-Rupp Pumps 12B22-B 1059806 thru 1343819 User Manual

Page 20

background image

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP STOPS OR

FAILS TO DELIVER

RATED FLOW OR

PRESSURE (cont.)

PUMP REQUIRES

TOO MUCH

POWER

PUMP CLOGS

FREQUENTLY

Free impeller of debris.

Impeller clogged.

Discharge head too low.

Dilute if possible.

Liquid solution too thick.

Adjust discharge valve.

Open discharge valve fully to in-
crease flow rate, and run power
source at maximum governed
speed.

Discharge flow too slow.

EXCESSIVE NOISE

Cavitation in pump.

Reduce suction lift and/or friction
losses in suction line. Record vac-
uum and pressure gauge readings
and consult local representative or
factory.

Secure mounting hardware.

Pump or drive not securely mounted.

Locate and eliminate source of air
bubble.

Pumping entrained air.

Suction check valve or foot valve
clogged or binding.

Clean valve.

Suction lift or discharge head too high.

Check piping installation and install
bypass line if needed. See

INSTAL-

LATION.

Impeller clogged or damaged.

Clean out debris; replace damaged
parts.

Leaking or worn seal or pump gasket.

Check pump vacuum. Replace
leaking or worn seal or gasket.

Pump running backwards.

Check direction of rotation and
correct by interchanging any two
motor leads at control box. (See
Pump Rotation, Section C).

Pump speed too slow.

Check driver output; check belts

or couplings for slippage.

Pump speed too high.

Check driver output check that

sheaves or couplings are correctly

sized.

BEARINGS RUN

TOO HOT

Bearing temperature is high, but
within limits.

Align drive properly.

Drive misaligned.

Check piping installation for proper
support.

Suction and discharge lines not prop-
erly supported.

Check for proper type and level of
lubricant.

Low or incorrect lubricant.

Check bearing temperature regular-
ly to monitor any increase.

OM--00589--03

10 SERIES

TROUBLESHOOTING

PAGE D -- 2