Positioning pump – Gorman-Rupp Pumps 14C2-4024T 1317426 and up User Manual
Page 9
OM−05780
10 SERIES
PAGE B − 2
INSTALLATION
c. Carefully read all warnings and cautions con-
tained in this manual or affixed to the pump,
and perform all duties indicated.
d. Check levels and lubricate as necessary. Re-
fer to LUBRICATION in the MAINTENANCE
AND REPAIR section of this manual and per-
form duties as instructed.
e. If the pump has been stored for more than 12
months, some of the components or lubri-
cants may have exceeded their maximum
shelf life. These must be inspected or re-
placed to ensure maximum pump service.
If the maximum shelf life has been exceeded, or if
anything appears to be abnormal, contact your
Gorman-Rupp distributor or the factory to deter-
mine the repair or updating policy. Do not put the
pump into service until appropriate action has
been taken.
Battery Specifications And Installation
Unless otherwise specified on the pump order, the
engine battery was not included with the unit. Re-
fer to the following specifications when selecting a
battery.
20.5L
x
12 Volts
960-975
365
175
8.75W
x
9.75H
Voltage
Cold
Reserve
Approx.
Crank
Capacity
Amp/
Overall
Amps
@80°F
Hr.
Dims.
@ 0°F
(Minutes)
Rating
(Inches)
Table 1. Battery Specifications
Refer to the information accompanying the battery
and/or electrolyte solution for activation and charg-
ing instructions.
Before installing the battery, clean the positive and
negative cable connectors, and the battery termi-
nals. Secure the battery by tightening the
holddown brackets. The terminals and clamps
may be coated with petroleum jelly to retard corro-
sion. Connect and tighten the positive cable first,
then the negative cable.
POSITIONING PUMP
Lifting
Pump unit weights will vary depending on the
mounting and drive provided. Check the shipping
tag on the unit packaging for the actual weight, and
use lifting equipment with appropriate capacity.
Drain the pump and remove all customer-installed
equipment such as suction and discharge hoses
or piping before attempting to lift existing, installed
units.
The pump assembly can be seriously
damaged if the cables or chains used to lift
and move the unit are improperly wrapped
around the pump.
After mounting the pump end to the engine and
base, use lifting equipment with a capacity of at
least 5 times the weight of the complete unit.
Mounting
Locate the pump in an accessible place as close as
practical to the liquid being pumped. Level mount-
ing is essential for proper operation.
The pump may have to be supported or shimmed
to provide for level operation or to eliminate vibra-
tion.
If the pump has been mounted on a moveable
base, make certain the base is stationary by setting
the brake and blocking the wheels before attempt-
ing to operate the pump.
To ensure sufficient lubrication and fuel supply to
the engine, do not position the pump and engine
more than 15
_ off horizontal for continuous opera-
tion. The pump and engine may be positioned up
to 30
_ off horizontal for intermittent operation
only; however, the engine manufacturer should be
consulted for continuous operation at angles
greater than 15
_.
Clearance
When positioning the pump, allow a minimum
clearance of 18 inches (457 mm) in front of the