Gorman-Rupp Pumps 14C2-4024T 1317426 and up User Manual
Page 37
OM−05780
10 SERIES
MAINTENANCE & REPAIR
PAGE E − 15
NOTE
The check valve assembly must be replaced as a
complete unit. Individual parts are not sold sepa-
rately.
Reach through the back cover opening with the as-
sembled check valve, and position the check valve
adaptor in the mounting slot in the suction flange.
Align the adaptor with the flange hole and secure
the assembly with the check valve pin (63).
NOTE
If the suction flange was removed, replace the gas-
ket (64), and apply ‘Permatex Aviation No. 3 Form-
A-Gasket’ or equivalent compound to the mating
surfaces.
Back Cover Installation
(Figure E−2)
If the wear plate (41) was removed for replace-
ment, carefully center it on the back cover and se-
cure it with the hardware (43 and 44). The wear
plate must be concentric to prevent binding when
the back cover is installed.
Clean any scale or debris from the contacting sur-
faces in the pump casing that might interfere or
prevent a good seal with the back cover. Replace
the back cover gasket (54), and slide the back
cover assembly into the pump casing. Be sure the
wear plate does not bind against the impeller.
NOTE
To ease future disassembly, apply a film of grease
or ‘Never-Seez’ on the back cover shoulder, or any
surface which contacts the pump casing. This ac-
tion will reduce rust and scale build-up.
Secure the back cover assembly by tightening the
cover clamp screw (46) against the clamp bar (45).
Do not over-tighten the clamp screw; it should be
just tight enough to ensure a good seal at the back
cover shoulder.
Final Pump Assembly
(Figure E−1)
Install any leveling shims used under the pump
casing mounting feet and secure the casing to the
base with the previously removed hardware (not
shown). Be sure the pump is secured to the base
and engine.
Install the suction and discharge lines, and open all
valves. Make certain that all piping connections are
tight, properly supported and secure.
Be sure the pump end and engine have been
properly lubricated, see LUBRICATION.
Remove the fill cover assembly (68, Figure E−2)
and fill the pump casing with clean liquid. Reinstall
the fill cover plate and tighten it.
Refer to OPERATION, Section C, and start the
pump.
LUBRICATION
Seal Assembly
(Figure E−2)
Fill the grease cup (13) through the grease fitting
with No. 2 lithium base grease until grease es-
capes from the relief hole. Turn the grease cup arm
counterclockwise until it is at the top of the stem;
this will release the spring to apply grease to the
seal (see Figure E−6).