beautypg.com

Gorman-Rupp Pumps 14C2-4024T 1317426 and up User Manual

Page 38

background image

10 SERIES

OM−05780

MAINTENANCE & REPAIR

PAGE E − 16

GREASE

FITTING

CROSS

ARM

POSITION

WHEN

EMPTY

POSITION

FOR

FILLING

POSITION

WHEN

IN USE

RELIEF

HOLE

NOTE:

When installing a new grease cup, lubricate
the cup as indicated on the installation tag
furnished with the grease cup.

Figure

E−6

. Automatic Lubricating Grease Cup

Bearings

(Figure E−2)

The intermediate was fully lubricated when
shipped from the factory. Check the oil level regu-
larly through the sight gauge (31),

and maintain it at

the middle of the gauge. When lubrication is re-
quired, add SAE No. 30 non-detergent oil through
the hole for the air vent (17). Do not over-lubricate.
Over-lubrication can cause the bearings to over-
heat, resulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.

Under normal conditions, drain the intermediate
once each year and refill with approximately 4
ounces (118 mL) of clean oil. Change the oil more
frequently if the pump is operated continuously or

installed in an environment with rapid temperature
change.

Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Engine

Consult the literature supplied with the engine, or
contact your local engine representative.