RS AND RD SERIES PUMPS
OM-03989
PAGE C - 6
OPERATION
Checking bearing temperatures by hand is inaccu
rate. Bearing temperatures can be measured ac
curately by placing a contact‐type thermometer
against the housing. Record this temperature for
future reference.
A sudden increase in bearing temperatures is a
warning that the bearings are at the point of failing
to operate properly. Make certain that the bearing
lubricant is of the proper viscosity and at the cor
rect level (see LUBRICATION in Section E). Bear
ing overheating can also be caused by shaft
misalignment and/or excessive vibration.
When pumps are first started, the bearings may
seem to run at temperatures above normal. Con
tinued operation should bring the temperatures
down to normal levels.
- RD2A31-B All serial numbers RD3A31-B All serial numbers RD3A31-BAR All serial numbers RD3A32-B All serial numbers RD3A32-BAR All serial numbers RD4A31-BAR All serial numbers RD4A31-B All serial numbers RD4A32-B All serial numbers RS2A31-B All serial numbers RD4A32-BAR All serial numbers RS2A31-BAR All serial numbers RS2A32-B All serial numbers RS2A32-BAR All serial numbers RS3A31-BAR All serial numbers RS3A31-B All serial numbers RS3A32-B All serial numbers RS3A32-BAR All serial numbers RS5A31-B All serial numbers RS5A31-BAR All serial numbers RS5A32-B All serial numbers RS5A32-BAR All serial numbers