Safety - section a – Gorman-Rupp Pumps 810A2-F5L 1322933 and up User Manual
Page 6
80 SERIES
OM−02396
PAGE A − 1
SAFETY
SAFETY - SECTION A
These warnings apply to 80 Series En-
gine Driven pumps. Refer to the manual
accompanying the engine before at-
tempting to begin operation.
Because pump installations are seldom
identical, this manual cannot possibly
provide detailed instructions and pre-
cautions for each specific application.
Therefore, it is the owner/installer’s re-
sponsibility to ensure that applications
not addressed in this manual are per-
formed only after establishing that nei-
ther operator safety nor pump integrity
are compromised by the installation.
Before attempting to install, operate, or
service this pump, familiarize yourself
with this manual, and with all other liter-
ature shipped with the pump. Unfamil-
iarity with all aspects of pump operation
covered in this manual could lead to de-
struction of equipment, injury, or death
to personnel.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man-
ual.
2. Switch off the engine ignition and
disconnect the positive battery
cable to ensure that the pump will
remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau-
tiously.
7. Drain the pump.
This pump is designed to handle dirty
water containing specified entrained
solids. Do not attempt to pump volatile,
corrosive, or flammable liquids which
may damage the pump or endanger per-
sonnel as a result of pump failure.
Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam-
age to equipment. Suction and dis-
charge hoses and piping must be re-
moved from the pump before lifting.
After the pump has been installed, make
certain that the pump and all piping or
hose connections are tight, properly
supported and secure before operation.
Do not operate the pump against a
closed discharge valve for long periods
of time. If operated against a closed dis-
charge valve, pump components will
deteriorate, and the liquid could come
to a boil, build pressure, and cause the
pump casing to rupture or explode.