INSTALLATION

ing, check for loose hardware at mating sur-
faces.

c. Carefully read all tags, decals, and markings

on the pump assembly, and perform all duties
indicated.

d. Check levels and lubricate as necessary. Re-

fer to

LUBRICATION in the MAINTENANCE

AND REPAIR section of this manual and per-
form duties as instructed.

e. If the pump and engine have been stored for

more than 12 months, some of the compo-
nents or lubricants may have exceeded their
maximum shelf life. These

must be inspected

or replaced to ensure maximum pump serv-
ice.

If the maximum shelf life has been exceeded, or if
anything appears to be abnormal, contact your
Gorman-Rupp distributor or the factory to deter-
mine the repair or updating policy.

Do not put the

pump into service until appropriate action has
been taken.

Battery Specifications And Installation

Unless otherwise specified on the pump order, the
engine battery was

not included with the unit. Re-

fer to the following specifications when selecting a
battery.

Table 1. Battery Specifications

Crank

@ 0

_

F

Reserve

Capacity

(Minutes)

@ 80

_

F

Overall

Dims.

(Inches)

960---975

365

20.5L

Cold

Amps

Approx.

Amp/

Hr.

Rating

175

8.75W
9.75H

x
x

Voltage

12 Volts

Refer to the information accompanying the battery
and/or electrolyte solution for activation and charg-
ing instructions.

Before installing the battery, clean the positive and
negative cable connectors, and the battery termi-
nals. Secure the battery by tightening the
holddown brackets. The terminals and clamps
may be coated with petroleum jelly to retard corro-
sion. Connect and tighten the positive cable first,
then the negative cable.

POSITIONING PUMP

Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam-
age to equipment. Suction and dis-
charge hoses and piping must be re-
moved from the pump before lifting.

Lifting

Use lifting equipment with a capacity of at least
14,500 pounds (6577 kg). This pump weighs ap-
proximately

2890 pounds (1311 kg), not including

the weight of accessories and optional wheel kit.
Customer installed equipment such as suction and
discharge piping

must be removed before at-

tempting to lift.

The pump assembly can be seriously

damaged if the cables or chains used to lift

and move the unit are improperly wrapped

around the pump.

Mounting

Locate the pump in an accessible place as close as
practical to the liquid being pumped. Level mount-
ing is essential for proper operation.

The pump may have to be supported or shimmed
to provide for level operation or to eliminate vibra-
tion.

If the pump has been mounted on a moveable
base, make certain the base is stationary by setting
the brake and blocking the wheels before attempt-
ing to operate the pump.

To ensure sufficient lubrication and fuel supply to
the engine,

do not position the pump and engine

more than 15_ off horizontal for continuous opera-
tion. The pump and engine may be positioned up
to 30_ off horizontal for

intermittent operation