Gorman-Rupp Pumps 810A2-F5L 1299234 thru 1322932 User Manual
Page 19
OM--02396
80 SERIES
TROUBLESHOOTING
PAGE D -- 2
Table 1. Trouble Shooting Chart (cont.)
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP STOPS OR FAILS
TO
DELIVER
RATED
FLOW OR PRESSURE
(cont.)
Leaking or worn seal or pump gas-
ket.
Suction intake not submerged at
proper level or sump too small.
Strainer clogged.
Impeller or other wearing parts worn
or damaged.
Impeller clogged.
Suction lift too high.
Pump speed too slow.
Check pump vacuum. Replace leak-
ing or worn seal or gasket.
Check installation and correct sub-
mergence as needed.
Check strainer and clean if neces-
sary.
Replace worn or damaged parts.
Check that impeller is properly cen-
tered and rotates freely.
Free impeller of debris.
Measure lift w/vacuum gauge. Re-
duce lift and/or friction losses in suc-
tion line.
Check engine output; consult engine
operation manual.
PUMP REQUIRES TOO
MUCH POWER
Pump speed too high.
Discharge head too low.
Liquid solution too thick.
Bearing(s) frozen.
Check engine output.
Adjust discharge valve.
Dilute if possible.
Disassemble pump and check bear-
ing(s).
PUMP CLOGS
FREQUENTLY
Discharge flow too slow.
Suction check valve or foot valve
clogged or binding.
Discharge line clogged or restricted;
hose kinked.
Open discharge valve fully to in-
crease flow rate, and run engine at
maximum governed speed.
Clean valve.
Check discharge lines; straighten
hose.
EXCESSIVE NOISE
Cavitation in pump.
Pumping entrained air.
Pump or drive not securely mounted.
Impeller clogged or damaged.
Reduce suction lift and/or friction
losses in suction line. Record vacu-
um and pressure gauge readings
and consult local representative or
factory.
Locate and eliminate source of air
bubble.
Secure mounting hardware.
Clean out debris; replace damaged
parts.