beautypg.com

Figure 5. automatic lubricating grease cup – Gorman-Rupp Pumps 810A2-F5L 1299234 thru 1322932 User Manual

Page 34

background image

OM--02396

80 SERIES

MAINTENANCE & REPAIR

PAGE E -- 13

GREASE

FITTING

CROSS

ARM

POSITION

WHEN

EMPTY

POSITION

FOR

FILLING

POSITION

WHEN

IN USE

RELIEF

HOLE

NOTE:

When installing a new grease cup, lubricate

the cup as indicated on the installation tag

furnished with the grease cup.

Figure 5. Automatic Lubricating Grease Cup

Bearings

(Figure 2)

The intermediate was fully lubricated when
shipped from the factory. Check the oil level regu-
larly through the sight gauge (57) and maintain it at
the middle of the gauge. When lubrication is re-
quired, add SAE No. 30 non-detergent oil through
the hole for the air vent (18).

Do not over-lubricate.

Over-lubrication can cause the bearings to over-
heat, resulting in premature bearing failure.

Under normal conditions, drain the intermediate
once each year and refill with clean oil. Change the
oil more frequently if the pump is operated continu-
ously or installed in an environment with rapid tem-
perature change.

Monitor the condition of the bearing lubri-

cant regularly for evidence of rust or mois-

ture condensation. This is especially im-

portant in areas where variable hot and

cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Engine

Consult the literature supplied with the engine, or
contact your local Deutz engine representative.